menuconfig BATT_MGMT
bool "Battery Management"
default y
select ADC
select EVENT_MGMT
select GPIO
select USB_MGMT
select NRFX_SAADC
help
Library for initializing and managing the battery subsystem.
if BATT_MGMT
config BATT_MGMT_EMPTY_THRESHOLD
int "Battery Empty Voltage (mV)"
default 3400
help
Voltage threshold treated as empty battery level (0/5).
config BATT_MGMT_SHUTDOWN_THRESHOLD
int "Critical shutdown voltage (mV)"
default 3300
help
If measured battery voltage is less than or equal to this threshold,
the device will power off to protect the battery.
config BATT_MGMT_FULL_THRESHOLD
int "Battery Full Voltage (mV)"
default 3980
help
Set the voltage level (in millivolts) that represents a full battery. Default is 3980 mV.
config BATT_MGMT_80P_THRESHOLD
int "Battery 80% Voltage (mV)"
default 3820
help
Set the voltage level (in millivolts) that represents 80% battery. Default is 3820 mV.
config BATT_MGMT_50P_THRESHOLD
int "Battery 50% Voltage (mV)"
default 3720
help
Set the voltage level (in millivolts) that represents 50% battery. Default is 3720 mV.
config BATT_MGMT_20P_THRESHOLD
int "Battery 20% Voltage (mV)"
default 3620
help
Set the voltage level (in millivolts) that represents 20% battery. Default is 3620 mV.
config BATT_MGMT_CHG_BLINKING_WINDOW_MS
int "Charger blinking detection window (ms)"
default 700
help
Time window to detect charger pin blinking (state changes). If the pin state
changes within this window, it's considered blinking (error state).
config BATT_MGMT_STANDBY_MEASURE_INTERVAL_MIN
int "Standby measurement interval (minutes)"
default 360
help
Measurement interval while idle in standby (no charging, no BLE, no audio).
config BATT_MGMT_ACTIVE_MEASURE_INTERVAL_MIN
int "Active measurement interval (minutes)"
default 1
help
Measurement interval while charging or BLE connected.
config BATT_MGMT_AUDIO_COOLDOWN_SEC
int "Audio cooldown before next measure (seconds)"
default 60
help
Delay before restarting periodic battery measurement after audio playback ends.
config BATT_MGMT_MONITOR_THREAD_STACK_SIZE
int "Battery monitor thread stack size"
default 1024
help
Stack size for the USB-triggered charger status monitor thread.
config BATT_MGMT_MONITOR_THREAD_PRIORITY
int "Battery monitor thread priority"
default 7
help
Cooperative priority for the monitor thread (lower number = higher priority).
config BATT_MGMT_BLINK_INTERVAL_LOGGING
bool "Enable logging of charger pin blinking intervals"
default n
help
If enabled, logs the time intervals between charger pin state changes, which can help diagnose charger connection issues.
module = BATT_MGMT
module-str = batt_mgmt
source "subsys/logging/Kconfig.template.log_config"
endif # BATT_MGMT