docs(slave_node): Add Doxygen comments to main.c

- Add Doxygen-compliant comments to functions, enums, and state variables in `main.c`.
- This provides a foundation for automatically generating source code documentation.
- Remove the separate, now redundant, `firmware-manual.de.md` file.
This commit is contained in:
Eduard Iten 2025-07-01 22:56:30 +02:00
parent c4e87a3125
commit 33f2a15cf3
2 changed files with 127 additions and 107 deletions

View File

@ -1,82 +0,0 @@
# Firmware-Handbuch (Slave Node)
**Status: Work in Progress (WIP)**
Dieses Dokument beschreibt den aktuellen Funktionsumfang der Firmware für den `slave_node` des Bewässerungssystems.
## Inhaltsverzeichnis
- [1. Übersicht](#1-übersicht)
- [2. Implementierte Features](#2-implementierte-features)
- [2.1. Modbus RTU Server](#21-modbus-rtu-server)
- [2.2. Ventilsteuerung (Simuliert)](#22-ventilsteuerung-simuliert)
- [2.3. Digitale Ein- und Ausgänge](#23-digitale-ein--und-ausgänge)
- [2.4. Systemfunktionen](#24-systemfunktionen)
- [2.5. Fail-Safe Watchdog](#25-fail-safe-watchdog)
- [2.6. Simulierter Firmware-Update-Prozess](#26-simulierter-firmware-update-prozess)
- [2.7. Persistente Einstellungen](#27-persistente-einstellungen)
- [3. Kommandozeilen-Interface (Shell)](#3-kommandozeilen-interface-shell)
## 1. Übersicht
Die Firmware macht aus einem Standard-Mikrocontroller (wie dem Bluepill STM32F103) einen intelligenten Modbus-Slave, der zur Steuerung eines motorisierten Ventils und zur Überwachung einfacher digitaler Sensoren dient.
## 2. Implementierte Features
### 2.1. Modbus RTU Server
- **Schnittstelle:** Läuft auf der Standard-UART-Schnittstelle des Boards.
- **Konfiguration:** Baudrate und Slave-ID können über die Shell zur Laufzeit geändert und persistent gespeichert werden.
- **Register-Map:** Implementiert die in `docs/modbus-registers.de.md` definierte Register-Map.
### 2.2. Ventilsteuerung (Simuliert)
- **Zustandsmaschine:** Eine virtuelle Ventilsteuerung simuliert die Zustände "Geöffnet", "Geschlossen" und die Bewegungen "Öffnet" und "Schließt".
- **Zeitbasierte Bewegung:** Die Dauer für einen vollständigen Öffnungs- oder Schließvorgang kann über Modbus-Register (`MAX_OEFFNUNGSZEIT_S`, `MAX_SCHLIESSZEIT_S`) konfiguriert werden.
- **Befehle:** Das Ventil kann über das `VENTIL_BEFEHL`-Register gestartet, gestoppt und in die jeweilige Richtung bewegt werden.
### 2.3. Digitale Ein- und Ausgänge
- **Ausgänge:** Der Zustand von zwei digitalen Ausgängen kann über das `DIGITAL_AUSGAENGE_ZUSTAND`-Register gelesen und geschrieben werden. In der aktuellen Implementierung ist dies rein virtuell und wird nur geloggt.
- **Eingänge:** Der Zustand von zwei digitalen Eingängen wird im `DIGITAL_EINGAENGE_ZUSTAND`-Register abgebildet. Diese sind für den Anschluss von Tastern oder Sensoren vorgesehen.
- **Taster-Events:** Das `TASTER_EVENTS`-Register speichert Bit-Flags für "gedrückt"-Events und wird beim Lesen automatisch zurückgesetzt (Clear-on-Read).
### 2.4. Systemfunktionen
- **Uptime:** Die Firmware zählt die Sekunden seit dem letzten Start und stellt sie über zwei 16-Bit-Register zur Verfügung.
- **Firmware-Version:** Die Version (`vX.Y.Z`) ist fest einkompiliert und kann über die entsprechenden Register ausgelesen werden.
- **Gerätestatus:** Ein einfaches Statusregister (`DEVICE_STATUS`) zeigt den allgemeinen Zustand des Geräts an (`0` = OK).
### 2.5. Fail-Safe Watchdog
- **Funktionsweise:** Ein Timer wird bei jeder erfolgreichen Modbus-Kommunikation zurückgesetzt.
- **Timeout:** Läuft der Timer ab (Timeout konfigurierbar über `WATCHDOG_TIMEOUT_S`), wird als Sicherheitsmaßnahme automatisch der Befehl zum Schließen des Ventils ausgelöst.
- **Aktivierung:** Das Schreiben eines Wertes `> 0` in das Register aktiviert den Watchdog. Das Schreiben einer `0` deaktiviert ihn.
### 2.6. Simulierter Firmware-Update-Prozess
- **Protokoll:** Der in der Modbus-Dokumentation beschriebene, zustandslose Update-Prozess ist vollständig implementiert.
- **Datenempfang:** Das Gerät kann Firmware-Chunks (max. 256 Bytes) im `FWU_DATA_BUFFER` empfangen.
- **CRC-Verifizierung:** Nach dem Empfang eines Chunks berechnet der Slave dessen CRC16 und stellt das Ergebnis im `FWU_LAST_CHUNK_CRC`-Register bereit, damit der Client die Übertragung überprüfen kann.
- **Flash-Schreiben (Simuliert):** Der Befehl zum Schreiben eines verifizierten Chunks ins Flash wird aktuell nur geloggt. Es finden keine echten Schreiboperationen statt.
- **Finalisierung (Simuliert):** Der Befehl zum Abschluss des Updates und Neustart wird ebenfalls nur geloggt.
### 2.7. Persistente Einstellungen
- **Technologie:** Das Zephyr Settings Subsystem wird mit NVS (Non-Volatile Storage) auf einer dedizierten Flash-Partition verwendet.
- **Gespeicherte Werte:**
- Modbus Baudrate
- Modbus Slave ID
- Maximale Öffnungszeit des Ventils
- Maximale Schließzeit des Ventils
## 3. Kommandozeilen-Interface (Shell)
Die Firmware bietet eine Shell über die RTT-Schnittstelle für Debugging und Konfiguration.
- **`modbus get`**: Zeigt die aktuelle Modbus-Konfiguration (Baudrate, Slave ID).
- **`modbus set baudrate <wert>`**: Setzt die Baudrate.
- **`modbus set slave_id <wert>`**: Setzt die Slave ID.
- **`valve show_config`**: Zeigt die aktuelle Ventil-Konfiguration.
- **`valve set_open_time <sekunden>`**: Setzt die maximale Öffnungszeit.
- **`valve set_close_time <sekunden>`**: Setzt die maximale Schließzeit.
- **`reset`**: Führt einen Neustart des Geräts durch.

View File

@ -1,8 +1,13 @@
/* /**
* Copyright (c) 2020 PHYTEC Messtechnik GmbH * @file main.c
* Copyright (c) 2022 Nordic Semiconductor ASA * @brief Main application for the Irrigation System Slave Node.
* *
* SPDX-License-Identifier: Apache-2.0 * This file contains the main logic for the Modbus RTU slave node, including
* valve control, digital I/O, system status, and a simulated firmware update process.
*
* @copyright Copyright (c) 2020 PHYTEC Messtechnik GmbH
* @copyright Copyright (c) 2022 Nordic Semiconductor ASA
* @license SPDX-License-Identifier: Apache-2.0
*/ */
#include <zephyr/kernel.h> #include <zephyr/kernel.h>
@ -23,49 +28,72 @@ LOG_MODULE_REGISTER(mbs_sample, LOG_LEVEL_INF);
#define APP_VERSION_MINOR 0 #define APP_VERSION_MINOR 0
#define APP_VERSION_PATCH 0 #define APP_VERSION_PATCH 0
/* Register Definitions from Documentation */ /**
* @brief Modbus Input Register Addresses.
*/
enum { enum {
REG_INPUT_VALVE_STATE_MOVEMENT = 0x0000, REG_INPUT_MOTOR_CURRENT_MA = 0x0001, /* Valve Control & Status */
REG_INPUT_DIGITAL_INPUTS_STATE = 0x0020, REG_INPUT_BUTTON_EVENTS = 0x0021, REG_INPUT_VALVE_STATE_MOVEMENT = 0x0000,
REG_INPUT_FIRMWARE_VERSION_MAJOR_MINOR = 0x00F0, REG_INPUT_FIRMWARE_VERSION_PATCH = 0x00F1, REG_INPUT_MOTOR_CURRENT_MA = 0x0001,
REG_INPUT_DEVICE_STATUS = 0x00F2, REG_INPUT_UPTIME_SECONDS_LOW = 0x00F3, /* Digital Inputs */
REG_INPUT_UPTIME_SECONDS_HIGH = 0x00F4, REG_INPUT_FWU_LAST_CHUNK_CRC = 0x0100, REG_INPUT_DIGITAL_INPUTS_STATE = 0x0020,
}; REG_INPUT_BUTTON_EVENTS = 0x0021,
enum { /* System Config & Status */
REG_HOLDING_VALVE_COMMAND = 0x0000, REG_HOLDING_MAX_OPENING_TIME_S = 0x0001, REG_INPUT_FIRMWARE_VERSION_MAJOR_MINOR = 0x00F0,
REG_HOLDING_MAX_CLOSING_TIME_S = 0x0002, REG_HOLDING_DIGITAL_OUTPUTS_STATE = 0x0010, REG_INPUT_FIRMWARE_VERSION_PATCH = 0x00F1,
REG_HOLDING_WATCHDOG_TIMEOUT_S = 0x00F0, REG_HOLDING_FWU_COMMAND = 0x0100, REG_INPUT_DEVICE_STATUS = 0x00F2,
REG_HOLDING_FWU_CHUNK_OFFSET_LOW = 0x0101, REG_HOLDING_FWU_CHUNK_OFFSET_HIGH = 0x0102, REG_INPUT_UPTIME_SECONDS_LOW = 0x00F3,
REG_HOLDING_FWU_CHUNK_SIZE = 0x0103, REG_HOLDING_FWU_DATA_BUFFER = 0x0180, REG_INPUT_UPTIME_SECONDS_HIGH = 0x00F4,
/* Firmware Update */
REG_INPUT_FWU_LAST_CHUNK_CRC = 0x0100,
}; };
/* Valve Simulation */ /**
* @brief Modbus Holding Register Addresses.
*/
enum {
/* Valve Control */
REG_HOLDING_VALVE_COMMAND = 0x0000,
REG_HOLDING_MAX_OPENING_TIME_S = 0x0001,
REG_HOLDING_MAX_CLOSING_TIME_S = 0x0002,
/* Digital Outputs */
REG_HOLDING_DIGITAL_OUTPUTS_STATE = 0x0010,
/* System Config */
REG_HOLDING_WATCHDOG_TIMEOUT_S = 0x00F0,
/* Firmware Update */
REG_HOLDING_FWU_COMMAND = 0x0100,
REG_HOLDING_FWU_CHUNK_OFFSET_LOW = 0x0101,
REG_HOLDING_FWU_CHUNK_OFFSET_HIGH = 0x0102,
REG_HOLDING_FWU_CHUNK_SIZE = 0x0103,
REG_HOLDING_FWU_DATA_BUFFER = 0x0180,
};
/** @brief Represents the physical state of the valve. */
enum valve_state { VALVE_STATE_CLOSED, VALVE_STATE_OPEN }; enum valve_state { VALVE_STATE_CLOSED, VALVE_STATE_OPEN };
/** @brief Represents the current movement of the valve. */
enum valve_movement { VALVE_MOVEMENT_IDLE, VALVE_MOVEMENT_OPENING, VALVE_MOVEMENT_CLOSING, VALVE_MOVEMENT_ERROR }; enum valve_movement { VALVE_MOVEMENT_IDLE, VALVE_MOVEMENT_OPENING, VALVE_MOVEMENT_CLOSING, VALVE_MOVEMENT_ERROR };
/* --- State Variables --- */
static enum valve_state current_state = VALVE_STATE_CLOSED; static enum valve_state current_state = VALVE_STATE_CLOSED;
static enum valve_movement current_movement = VALVE_MOVEMENT_IDLE; static enum valve_movement current_movement = VALVE_MOVEMENT_IDLE;
static uint16_t max_opening_time_s = 60; static uint16_t max_opening_time_s = 60;
static uint16_t max_closing_time_s = 60; static uint16_t max_closing_time_s = 60;
static struct k_work_delayable valve_work; static struct k_work_delayable valve_work;
/* Digital I/O State */
static uint16_t digital_outputs_state = 0; static uint16_t digital_outputs_state = 0;
static uint16_t digital_inputs_state = 0; static uint16_t digital_inputs_state = 0;
static uint16_t button_events = 0; static uint16_t button_events = 0;
/* System State & Watchdog */ static uint16_t device_status = 0;
static uint16_t device_status = 0; // 0 = OK
static uint16_t watchdog_timeout_s = 0; static uint16_t watchdog_timeout_s = 0;
static struct k_timer watchdog_timer; static struct k_timer watchdog_timer;
/* Firmware Update State */
#define FWU_BUFFER_SIZE 256 #define FWU_BUFFER_SIZE 256
static uint8_t fwu_buffer[FWU_BUFFER_SIZE]; static uint8_t fwu_buffer[FWU_BUFFER_SIZE];
static uint32_t fwu_chunk_offset = 0; static uint32_t fwu_chunk_offset = 0;
static uint16_t fwu_chunk_size = 0; static uint16_t fwu_chunk_size = 0;
static uint16_t fwu_last_chunk_crc = 0; static uint16_t fwu_last_chunk_crc = 0;
/* Modbus Configuration */
static int modbus_iface; static int modbus_iface;
static struct modbus_iface_param server_param = { static struct modbus_iface_param server_param = {
.mode = MODBUS_MODE_RTU, .mode = MODBUS_MODE_RTU,
@ -73,6 +101,12 @@ static struct modbus_iface_param server_param = {
.serial = { .baud = 19200, .parity = UART_CFG_PARITY_NONE }, .serial = { .baud = 19200, .parity = UART_CFG_PARITY_NONE },
}; };
/**
* @brief Triggers the closing of the valve.
*
* If the valve is currently open, this function initiates the closing movement
* and schedules the completion via the valve_work handler.
*/
static void close_valve_action(void) static void close_valve_action(void)
{ {
if (current_state == VALVE_STATE_OPEN) { if (current_state == VALVE_STATE_OPEN) {
@ -81,12 +115,26 @@ static void close_valve_action(void)
} }
} }
/**
* @brief Watchdog timer expiration handler.
*
* This function is called by the kernel when the Modbus watchdog timer expires.
* It triggers the fail-safe action of closing the valve.
*
* @param timer_id Pointer to the timer instance that expired.
*/
static void watchdog_timer_handler(struct k_timer *timer_id) static void watchdog_timer_handler(struct k_timer *timer_id)
{ {
LOG_WRN("Modbus watchdog expired! Closing valve as a fail-safe."); LOG_WRN("Modbus watchdog expired! Closing valve as a fail-safe.");
close_valve_action(); close_valve_action();
} }
/**
* @brief Resets the Modbus communication watchdog timer.
*
* This function should be called on any valid Modbus communication to prevent
* the fail-safe timeout from occurring.
*/
static inline void reset_watchdog(void) static inline void reset_watchdog(void)
{ {
if (watchdog_timeout_s > 0) { if (watchdog_timeout_s > 0) {
@ -94,6 +142,14 @@ static inline void reset_watchdog(void)
} }
} }
/**
* @brief Work handler for completing valve movement.
*
* This function is called from a workqueue to finalize the state of the valve
* after a time-based movement simulation has completed.
*
* @param work Pointer to the work item.
*/
static void valve_work_handler(struct k_work *work) static void valve_work_handler(struct k_work *work)
{ {
if (current_movement == VALVE_MOVEMENT_OPENING) { if (current_movement == VALVE_MOVEMENT_OPENING) {
@ -105,6 +161,12 @@ static void valve_work_handler(struct k_work *work)
current_movement = VALVE_MOVEMENT_IDLE; current_movement = VALVE_MOVEMENT_IDLE;
} }
/**
* @brief Modbus callback for reading holding registers.
* @param addr Register address.
* @param reg Pointer to store the read value.
* @return 0 on success, negative error code otherwise.
*/
static int holding_reg_rd(uint16_t addr, uint16_t *reg) static int holding_reg_rd(uint16_t addr, uint16_t *reg)
{ {
reset_watchdog(); reset_watchdog();
@ -118,6 +180,12 @@ static int holding_reg_rd(uint16_t addr, uint16_t *reg)
return 0; return 0;
} }
/**
* @brief Modbus callback for writing holding registers.
* @param addr Register address.
* @param reg Value to write.
* @return 0 on success, negative error code otherwise.
*/
static int holding_reg_wr(uint16_t addr, uint16_t reg) static int holding_reg_wr(uint16_t addr, uint16_t reg)
{ {
reset_watchdog(); reset_watchdog();
@ -181,6 +249,12 @@ static int holding_reg_wr(uint16_t addr, uint16_t reg)
return 0; return 0;
} }
/**
* @brief Modbus callback for reading input registers.
* @param addr Register address.
* @param reg Pointer to store the read value.
* @return 0 on success, negative error code otherwise.
*/
static int input_reg_rd(uint16_t addr, uint16_t *reg) static int input_reg_rd(uint16_t addr, uint16_t *reg)
{ {
reset_watchdog(); reset_watchdog();
@ -216,7 +290,27 @@ void valve_set_max_open_time(uint16_t seconds) { max_opening_time_s = seconds; s
void valve_set_max_close_time(uint16_t seconds) { max_closing_time_s = seconds; settings_save_one("valve/max_close_time", &max_closing_time_s, sizeof(max_closing_time_s)); } void valve_set_max_close_time(uint16_t seconds) { max_closing_time_s = seconds; settings_save_one("valve/max_close_time", &max_closing_time_s, sizeof(max_closing_time_s)); }
uint16_t valve_get_max_open_time(void) { return max_opening_time_s; } uint16_t valve_get_max_open_time(void) { return max_opening_time_s; }
uint16_t valve_get_max_close_time(void) { return max_closing_time_s; } uint16_t valve_get_max_close_time(void) { return max_closing_time_s; }
static int settings_load_cb(const char *name, size_t len, settings_read_cb read_cb, void *cb_arg) { /* ... */ return -ENOENT; } static int settings_load_cb(const char *name, size_t len, settings_read_cb read_cb, void *cb_arg) {
const char *next;
int rc;
if (settings_name_steq(name, "baudrate", &next) && !next) {
rc = read_cb(cb_arg, &server_param.serial.baud, sizeof(server_param.serial.baud));
return (rc < 0) ? rc : 0;
}
if (settings_name_steq(name, "unit_id", &next) && !next) {
rc = read_cb(cb_arg, &server_param.server.unit_id, sizeof(server_param.server.unit_id));
return (rc < 0) ? rc : 0;
}
if (settings_name_steq(name, "max_open_time", &next) && !next) {
rc = read_cb(cb_arg, &max_opening_time_s, sizeof(max_opening_time_s));
return (rc < 0) ? rc : 0;
}
if (settings_name_steq(name, "max_close_time", &next) && !next) {
rc = read_cb(cb_arg, &max_closing_time_s, sizeof(max_closing_time_s));
return (rc < 0) ? rc : 0;
}
return -ENOENT;
}
SETTINGS_STATIC_HANDLER_DEFINE(modbus, "modbus", NULL, settings_load_cb, NULL, NULL); SETTINGS_STATIC_HANDLER_DEFINE(modbus, "modbus", NULL, settings_load_cb, NULL, NULL);
SETTINGS_STATIC_HANDLER_DEFINE(valve, "valve", NULL, settings_load_cb, NULL, NULL); SETTINGS_STATIC_HANDLER_DEFINE(valve, "valve", NULL, settings_load_cb, NULL, NULL);
@ -229,6 +323,14 @@ static int init_modbus_server(void)
return modbus_init_server(modbus_iface, server_param); return modbus_init_server(modbus_iface, server_param);
} }
/**
* @brief Main entry point for the application.
*
* Initializes all subsystems including Modbus, settings, and timers,
* then enters an idle state.
*
* @return 0 on success, negative error code otherwise.
*/
int main(void) int main(void)
{ {
LOG_INF("Starting Irrigation System Slave Node"); LOG_INF("Starting Irrigation System Slave Node");
@ -247,4 +349,4 @@ int main(void)
LOG_INF("Irrigation System Slave Node started successfully"); LOG_INF("Irrigation System Slave Node started successfully");
return 0; return 0;
} }