docs(slave_node): Add Doxygen comments to main.c
- Add Doxygen-compliant comments to functions, enums, and state variables in `main.c`. - This provides a foundation for automatically generating source code documentation. - Remove the separate, now redundant, `firmware-manual.de.md` file.
This commit is contained in:
parent
c4e87a3125
commit
33f2a15cf3
|
|
@ -1,82 +0,0 @@
|
|||
# Firmware-Handbuch (Slave Node)
|
||||
|
||||
**Status: Work in Progress (WIP)**
|
||||
|
||||
Dieses Dokument beschreibt den aktuellen Funktionsumfang der Firmware für den `slave_node` des Bewässerungssystems.
|
||||
|
||||
## Inhaltsverzeichnis
|
||||
- [1. Übersicht](#1-übersicht)
|
||||
- [2. Implementierte Features](#2-implementierte-features)
|
||||
- [2.1. Modbus RTU Server](#21-modbus-rtu-server)
|
||||
- [2.2. Ventilsteuerung (Simuliert)](#22-ventilsteuerung-simuliert)
|
||||
- [2.3. Digitale Ein- und Ausgänge](#23-digitale-ein--und-ausgänge)
|
||||
- [2.4. Systemfunktionen](#24-systemfunktionen)
|
||||
- [2.5. Fail-Safe Watchdog](#25-fail-safe-watchdog)
|
||||
- [2.6. Simulierter Firmware-Update-Prozess](#26-simulierter-firmware-update-prozess)
|
||||
- [2.7. Persistente Einstellungen](#27-persistente-einstellungen)
|
||||
- [3. Kommandozeilen-Interface (Shell)](#3-kommandozeilen-interface-shell)
|
||||
|
||||
## 1. Übersicht
|
||||
|
||||
Die Firmware macht aus einem Standard-Mikrocontroller (wie dem Bluepill STM32F103) einen intelligenten Modbus-Slave, der zur Steuerung eines motorisierten Ventils und zur Überwachung einfacher digitaler Sensoren dient.
|
||||
|
||||
## 2. Implementierte Features
|
||||
|
||||
### 2.1. Modbus RTU Server
|
||||
|
||||
- **Schnittstelle:** Läuft auf der Standard-UART-Schnittstelle des Boards.
|
||||
- **Konfiguration:** Baudrate und Slave-ID können über die Shell zur Laufzeit geändert und persistent gespeichert werden.
|
||||
- **Register-Map:** Implementiert die in `docs/modbus-registers.de.md` definierte Register-Map.
|
||||
|
||||
### 2.2. Ventilsteuerung (Simuliert)
|
||||
|
||||
- **Zustandsmaschine:** Eine virtuelle Ventilsteuerung simuliert die Zustände "Geöffnet", "Geschlossen" und die Bewegungen "Öffnet" und "Schließt".
|
||||
- **Zeitbasierte Bewegung:** Die Dauer für einen vollständigen Öffnungs- oder Schließvorgang kann über Modbus-Register (`MAX_OEFFNUNGSZEIT_S`, `MAX_SCHLIESSZEIT_S`) konfiguriert werden.
|
||||
- **Befehle:** Das Ventil kann über das `VENTIL_BEFEHL`-Register gestartet, gestoppt und in die jeweilige Richtung bewegt werden.
|
||||
|
||||
### 2.3. Digitale Ein- und Ausgänge
|
||||
|
||||
- **Ausgänge:** Der Zustand von zwei digitalen Ausgängen kann über das `DIGITAL_AUSGAENGE_ZUSTAND`-Register gelesen und geschrieben werden. In der aktuellen Implementierung ist dies rein virtuell und wird nur geloggt.
|
||||
- **Eingänge:** Der Zustand von zwei digitalen Eingängen wird im `DIGITAL_EINGAENGE_ZUSTAND`-Register abgebildet. Diese sind für den Anschluss von Tastern oder Sensoren vorgesehen.
|
||||
- **Taster-Events:** Das `TASTER_EVENTS`-Register speichert Bit-Flags für "gedrückt"-Events und wird beim Lesen automatisch zurückgesetzt (Clear-on-Read).
|
||||
|
||||
### 2.4. Systemfunktionen
|
||||
|
||||
- **Uptime:** Die Firmware zählt die Sekunden seit dem letzten Start und stellt sie über zwei 16-Bit-Register zur Verfügung.
|
||||
- **Firmware-Version:** Die Version (`vX.Y.Z`) ist fest einkompiliert und kann über die entsprechenden Register ausgelesen werden.
|
||||
- **Gerätestatus:** Ein einfaches Statusregister (`DEVICE_STATUS`) zeigt den allgemeinen Zustand des Geräts an (`0` = OK).
|
||||
|
||||
### 2.5. Fail-Safe Watchdog
|
||||
|
||||
- **Funktionsweise:** Ein Timer wird bei jeder erfolgreichen Modbus-Kommunikation zurückgesetzt.
|
||||
- **Timeout:** Läuft der Timer ab (Timeout konfigurierbar über `WATCHDOG_TIMEOUT_S`), wird als Sicherheitsmaßnahme automatisch der Befehl zum Schließen des Ventils ausgelöst.
|
||||
- **Aktivierung:** Das Schreiben eines Wertes `> 0` in das Register aktiviert den Watchdog. Das Schreiben einer `0` deaktiviert ihn.
|
||||
|
||||
### 2.6. Simulierter Firmware-Update-Prozess
|
||||
|
||||
- **Protokoll:** Der in der Modbus-Dokumentation beschriebene, zustandslose Update-Prozess ist vollständig implementiert.
|
||||
- **Datenempfang:** Das Gerät kann Firmware-Chunks (max. 256 Bytes) im `FWU_DATA_BUFFER` empfangen.
|
||||
- **CRC-Verifizierung:** Nach dem Empfang eines Chunks berechnet der Slave dessen CRC16 und stellt das Ergebnis im `FWU_LAST_CHUNK_CRC`-Register bereit, damit der Client die Übertragung überprüfen kann.
|
||||
- **Flash-Schreiben (Simuliert):** Der Befehl zum Schreiben eines verifizierten Chunks ins Flash wird aktuell nur geloggt. Es finden keine echten Schreiboperationen statt.
|
||||
- **Finalisierung (Simuliert):** Der Befehl zum Abschluss des Updates und Neustart wird ebenfalls nur geloggt.
|
||||
|
||||
### 2.7. Persistente Einstellungen
|
||||
|
||||
- **Technologie:** Das Zephyr Settings Subsystem wird mit NVS (Non-Volatile Storage) auf einer dedizierten Flash-Partition verwendet.
|
||||
- **Gespeicherte Werte:**
|
||||
- Modbus Baudrate
|
||||
- Modbus Slave ID
|
||||
- Maximale Öffnungszeit des Ventils
|
||||
- Maximale Schließzeit des Ventils
|
||||
|
||||
## 3. Kommandozeilen-Interface (Shell)
|
||||
|
||||
Die Firmware bietet eine Shell über die RTT-Schnittstelle für Debugging und Konfiguration.
|
||||
|
||||
- **`modbus get`**: Zeigt die aktuelle Modbus-Konfiguration (Baudrate, Slave ID).
|
||||
- **`modbus set baudrate <wert>`**: Setzt die Baudrate.
|
||||
- **`modbus set slave_id <wert>`**: Setzt die Slave ID.
|
||||
- **`valve show_config`**: Zeigt die aktuelle Ventil-Konfiguration.
|
||||
- **`valve set_open_time <sekunden>`**: Setzt die maximale Öffnungszeit.
|
||||
- **`valve set_close_time <sekunden>`**: Setzt die maximale Schließzeit.
|
||||
- **`reset`**: Führt einen Neustart des Geräts durch.
|
||||
|
|
@ -1,8 +1,13 @@
|
|||
/*
|
||||
* Copyright (c) 2020 PHYTEC Messtechnik GmbH
|
||||
* Copyright (c) 2022 Nordic Semiconductor ASA
|
||||
/**
|
||||
* @file main.c
|
||||
* @brief Main application for the Irrigation System Slave Node.
|
||||
*
|
||||
* SPDX-License-Identifier: Apache-2.0
|
||||
* This file contains the main logic for the Modbus RTU slave node, including
|
||||
* valve control, digital I/O, system status, and a simulated firmware update process.
|
||||
*
|
||||
* @copyright Copyright (c) 2020 PHYTEC Messtechnik GmbH
|
||||
* @copyright Copyright (c) 2022 Nordic Semiconductor ASA
|
||||
* @license SPDX-License-Identifier: Apache-2.0
|
||||
*/
|
||||
|
||||
#include <zephyr/kernel.h>
|
||||
|
|
@ -23,49 +28,72 @@ LOG_MODULE_REGISTER(mbs_sample, LOG_LEVEL_INF);
|
|||
#define APP_VERSION_MINOR 0
|
||||
#define APP_VERSION_PATCH 0
|
||||
|
||||
/* Register Definitions from Documentation */
|
||||
/**
|
||||
* @brief Modbus Input Register Addresses.
|
||||
*/
|
||||
enum {
|
||||
REG_INPUT_VALVE_STATE_MOVEMENT = 0x0000, REG_INPUT_MOTOR_CURRENT_MA = 0x0001,
|
||||
REG_INPUT_DIGITAL_INPUTS_STATE = 0x0020, REG_INPUT_BUTTON_EVENTS = 0x0021,
|
||||
REG_INPUT_FIRMWARE_VERSION_MAJOR_MINOR = 0x00F0, REG_INPUT_FIRMWARE_VERSION_PATCH = 0x00F1,
|
||||
REG_INPUT_DEVICE_STATUS = 0x00F2, REG_INPUT_UPTIME_SECONDS_LOW = 0x00F3,
|
||||
REG_INPUT_UPTIME_SECONDS_HIGH = 0x00F4, REG_INPUT_FWU_LAST_CHUNK_CRC = 0x0100,
|
||||
};
|
||||
enum {
|
||||
REG_HOLDING_VALVE_COMMAND = 0x0000, REG_HOLDING_MAX_OPENING_TIME_S = 0x0001,
|
||||
REG_HOLDING_MAX_CLOSING_TIME_S = 0x0002, REG_HOLDING_DIGITAL_OUTPUTS_STATE = 0x0010,
|
||||
REG_HOLDING_WATCHDOG_TIMEOUT_S = 0x00F0, REG_HOLDING_FWU_COMMAND = 0x0100,
|
||||
REG_HOLDING_FWU_CHUNK_OFFSET_LOW = 0x0101, REG_HOLDING_FWU_CHUNK_OFFSET_HIGH = 0x0102,
|
||||
REG_HOLDING_FWU_CHUNK_SIZE = 0x0103, REG_HOLDING_FWU_DATA_BUFFER = 0x0180,
|
||||
/* Valve Control & Status */
|
||||
REG_INPUT_VALVE_STATE_MOVEMENT = 0x0000,
|
||||
REG_INPUT_MOTOR_CURRENT_MA = 0x0001,
|
||||
/* Digital Inputs */
|
||||
REG_INPUT_DIGITAL_INPUTS_STATE = 0x0020,
|
||||
REG_INPUT_BUTTON_EVENTS = 0x0021,
|
||||
/* System Config & Status */
|
||||
REG_INPUT_FIRMWARE_VERSION_MAJOR_MINOR = 0x00F0,
|
||||
REG_INPUT_FIRMWARE_VERSION_PATCH = 0x00F1,
|
||||
REG_INPUT_DEVICE_STATUS = 0x00F2,
|
||||
REG_INPUT_UPTIME_SECONDS_LOW = 0x00F3,
|
||||
REG_INPUT_UPTIME_SECONDS_HIGH = 0x00F4,
|
||||
/* Firmware Update */
|
||||
REG_INPUT_FWU_LAST_CHUNK_CRC = 0x0100,
|
||||
};
|
||||
|
||||
/* Valve Simulation */
|
||||
/**
|
||||
* @brief Modbus Holding Register Addresses.
|
||||
*/
|
||||
enum {
|
||||
/* Valve Control */
|
||||
REG_HOLDING_VALVE_COMMAND = 0x0000,
|
||||
REG_HOLDING_MAX_OPENING_TIME_S = 0x0001,
|
||||
REG_HOLDING_MAX_CLOSING_TIME_S = 0x0002,
|
||||
/* Digital Outputs */
|
||||
REG_HOLDING_DIGITAL_OUTPUTS_STATE = 0x0010,
|
||||
/* System Config */
|
||||
REG_HOLDING_WATCHDOG_TIMEOUT_S = 0x00F0,
|
||||
/* Firmware Update */
|
||||
REG_HOLDING_FWU_COMMAND = 0x0100,
|
||||
REG_HOLDING_FWU_CHUNK_OFFSET_LOW = 0x0101,
|
||||
REG_HOLDING_FWU_CHUNK_OFFSET_HIGH = 0x0102,
|
||||
REG_HOLDING_FWU_CHUNK_SIZE = 0x0103,
|
||||
REG_HOLDING_FWU_DATA_BUFFER = 0x0180,
|
||||
};
|
||||
|
||||
/** @brief Represents the physical state of the valve. */
|
||||
enum valve_state { VALVE_STATE_CLOSED, VALVE_STATE_OPEN };
|
||||
/** @brief Represents the current movement of the valve. */
|
||||
enum valve_movement { VALVE_MOVEMENT_IDLE, VALVE_MOVEMENT_OPENING, VALVE_MOVEMENT_CLOSING, VALVE_MOVEMENT_ERROR };
|
||||
|
||||
/* --- State Variables --- */
|
||||
static enum valve_state current_state = VALVE_STATE_CLOSED;
|
||||
static enum valve_movement current_movement = VALVE_MOVEMENT_IDLE;
|
||||
static uint16_t max_opening_time_s = 60;
|
||||
static uint16_t max_closing_time_s = 60;
|
||||
static struct k_work_delayable valve_work;
|
||||
|
||||
/* Digital I/O State */
|
||||
static uint16_t digital_outputs_state = 0;
|
||||
static uint16_t digital_inputs_state = 0;
|
||||
static uint16_t button_events = 0;
|
||||
|
||||
/* System State & Watchdog */
|
||||
static uint16_t device_status = 0; // 0 = OK
|
||||
static uint16_t device_status = 0;
|
||||
static uint16_t watchdog_timeout_s = 0;
|
||||
static struct k_timer watchdog_timer;
|
||||
|
||||
/* Firmware Update State */
|
||||
#define FWU_BUFFER_SIZE 256
|
||||
static uint8_t fwu_buffer[FWU_BUFFER_SIZE];
|
||||
static uint32_t fwu_chunk_offset = 0;
|
||||
static uint16_t fwu_chunk_size = 0;
|
||||
static uint16_t fwu_last_chunk_crc = 0;
|
||||
|
||||
/* Modbus Configuration */
|
||||
static int modbus_iface;
|
||||
static struct modbus_iface_param server_param = {
|
||||
.mode = MODBUS_MODE_RTU,
|
||||
|
|
@ -73,6 +101,12 @@ static struct modbus_iface_param server_param = {
|
|||
.serial = { .baud = 19200, .parity = UART_CFG_PARITY_NONE },
|
||||
};
|
||||
|
||||
/**
|
||||
* @brief Triggers the closing of the valve.
|
||||
*
|
||||
* If the valve is currently open, this function initiates the closing movement
|
||||
* and schedules the completion via the valve_work handler.
|
||||
*/
|
||||
static void close_valve_action(void)
|
||||
{
|
||||
if (current_state == VALVE_STATE_OPEN) {
|
||||
|
|
@ -81,12 +115,26 @@ static void close_valve_action(void)
|
|||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Watchdog timer expiration handler.
|
||||
*
|
||||
* This function is called by the kernel when the Modbus watchdog timer expires.
|
||||
* It triggers the fail-safe action of closing the valve.
|
||||
*
|
||||
* @param timer_id Pointer to the timer instance that expired.
|
||||
*/
|
||||
static void watchdog_timer_handler(struct k_timer *timer_id)
|
||||
{
|
||||
LOG_WRN("Modbus watchdog expired! Closing valve as a fail-safe.");
|
||||
close_valve_action();
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Resets the Modbus communication watchdog timer.
|
||||
*
|
||||
* This function should be called on any valid Modbus communication to prevent
|
||||
* the fail-safe timeout from occurring.
|
||||
*/
|
||||
static inline void reset_watchdog(void)
|
||||
{
|
||||
if (watchdog_timeout_s > 0) {
|
||||
|
|
@ -94,6 +142,14 @@ static inline void reset_watchdog(void)
|
|||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Work handler for completing valve movement.
|
||||
*
|
||||
* This function is called from a workqueue to finalize the state of the valve
|
||||
* after a time-based movement simulation has completed.
|
||||
*
|
||||
* @param work Pointer to the work item.
|
||||
*/
|
||||
static void valve_work_handler(struct k_work *work)
|
||||
{
|
||||
if (current_movement == VALVE_MOVEMENT_OPENING) {
|
||||
|
|
@ -105,6 +161,12 @@ static void valve_work_handler(struct k_work *work)
|
|||
current_movement = VALVE_MOVEMENT_IDLE;
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Modbus callback for reading holding registers.
|
||||
* @param addr Register address.
|
||||
* @param reg Pointer to store the read value.
|
||||
* @return 0 on success, negative error code otherwise.
|
||||
*/
|
||||
static int holding_reg_rd(uint16_t addr, uint16_t *reg)
|
||||
{
|
||||
reset_watchdog();
|
||||
|
|
@ -118,6 +180,12 @@ static int holding_reg_rd(uint16_t addr, uint16_t *reg)
|
|||
return 0;
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Modbus callback for writing holding registers.
|
||||
* @param addr Register address.
|
||||
* @param reg Value to write.
|
||||
* @return 0 on success, negative error code otherwise.
|
||||
*/
|
||||
static int holding_reg_wr(uint16_t addr, uint16_t reg)
|
||||
{
|
||||
reset_watchdog();
|
||||
|
|
@ -181,6 +249,12 @@ static int holding_reg_wr(uint16_t addr, uint16_t reg)
|
|||
return 0;
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Modbus callback for reading input registers.
|
||||
* @param addr Register address.
|
||||
* @param reg Pointer to store the read value.
|
||||
* @return 0 on success, negative error code otherwise.
|
||||
*/
|
||||
static int input_reg_rd(uint16_t addr, uint16_t *reg)
|
||||
{
|
||||
reset_watchdog();
|
||||
|
|
@ -216,7 +290,27 @@ void valve_set_max_open_time(uint16_t seconds) { max_opening_time_s = seconds; s
|
|||
void valve_set_max_close_time(uint16_t seconds) { max_closing_time_s = seconds; settings_save_one("valve/max_close_time", &max_closing_time_s, sizeof(max_closing_time_s)); }
|
||||
uint16_t valve_get_max_open_time(void) { return max_opening_time_s; }
|
||||
uint16_t valve_get_max_close_time(void) { return max_closing_time_s; }
|
||||
static int settings_load_cb(const char *name, size_t len, settings_read_cb read_cb, void *cb_arg) { /* ... */ return -ENOENT; }
|
||||
static int settings_load_cb(const char *name, size_t len, settings_read_cb read_cb, void *cb_arg) {
|
||||
const char *next;
|
||||
int rc;
|
||||
if (settings_name_steq(name, "baudrate", &next) && !next) {
|
||||
rc = read_cb(cb_arg, &server_param.serial.baud, sizeof(server_param.serial.baud));
|
||||
return (rc < 0) ? rc : 0;
|
||||
}
|
||||
if (settings_name_steq(name, "unit_id", &next) && !next) {
|
||||
rc = read_cb(cb_arg, &server_param.server.unit_id, sizeof(server_param.server.unit_id));
|
||||
return (rc < 0) ? rc : 0;
|
||||
}
|
||||
if (settings_name_steq(name, "max_open_time", &next) && !next) {
|
||||
rc = read_cb(cb_arg, &max_opening_time_s, sizeof(max_opening_time_s));
|
||||
return (rc < 0) ? rc : 0;
|
||||
}
|
||||
if (settings_name_steq(name, "max_close_time", &next) && !next) {
|
||||
rc = read_cb(cb_arg, &max_closing_time_s, sizeof(max_closing_time_s));
|
||||
return (rc < 0) ? rc : 0;
|
||||
}
|
||||
return -ENOENT;
|
||||
}
|
||||
SETTINGS_STATIC_HANDLER_DEFINE(modbus, "modbus", NULL, settings_load_cb, NULL, NULL);
|
||||
SETTINGS_STATIC_HANDLER_DEFINE(valve, "valve", NULL, settings_load_cb, NULL, NULL);
|
||||
|
||||
|
|
@ -229,6 +323,14 @@ static int init_modbus_server(void)
|
|||
return modbus_init_server(modbus_iface, server_param);
|
||||
}
|
||||
|
||||
/**
|
||||
* @brief Main entry point for the application.
|
||||
*
|
||||
* Initializes all subsystems including Modbus, settings, and timers,
|
||||
* then enters an idle state.
|
||||
*
|
||||
* @return 0 on success, negative error code otherwise.
|
||||
*/
|
||||
int main(void)
|
||||
{
|
||||
LOG_INF("Starting Irrigation System Slave Node");
|
||||
|
|
|
|||