Played around with the irrigaton system yaml
Signed-off-by: Eduard Iten <eduard@iten.pro>
This commit is contained in:
parent
6f304efb57
commit
ef966cb078
|
|
@ -1,3 +1,11 @@
|
||||||
|
# ===================================================================
|
||||||
|
# ESPHome Configuration - Final Version
|
||||||
|
#
|
||||||
|
# This version corrects the C++ function call inside the valve actions
|
||||||
|
# to use the correct `send` method from the ModbusDevice base class,
|
||||||
|
# which is compatible with the esp-idf framework.
|
||||||
|
# ===================================================================
|
||||||
|
|
||||||
esphome:
|
esphome:
|
||||||
name: irrigation-system
|
name: irrigation-system
|
||||||
friendly_name: Bewässerung
|
friendly_name: Bewässerung
|
||||||
|
|
@ -5,7 +13,7 @@ esphome:
|
||||||
esp32:
|
esp32:
|
||||||
board: esp32-c6-devkitm-1
|
board: esp32-c6-devkitm-1
|
||||||
framework:
|
framework:
|
||||||
type: esp-idf
|
type: esp-idf # Set to esp-idf as required by the ESP32-C6 board
|
||||||
|
|
||||||
wifi:
|
wifi:
|
||||||
ssid: !secret wifi_ssid
|
ssid: !secret wifi_ssid
|
||||||
|
|
@ -24,88 +32,135 @@ logger:
|
||||||
|
|
||||||
web_server:
|
web_server:
|
||||||
|
|
||||||
# UART-Bus für Modbus
|
# ===================================================================
|
||||||
|
# HARDWARE SETUP - COMPLETE
|
||||||
|
# ===================================================================
|
||||||
|
|
||||||
|
# --- UART for RS485 Communication ---
|
||||||
uart:
|
uart:
|
||||||
id: uart_bus
|
id: uart_bus
|
||||||
tx_pin: GPIO1
|
tx_pin: GPIO1
|
||||||
rx_pin: GPIO2
|
rx_pin: GPIO2
|
||||||
baud_rate: 9600
|
baud_rate: 9600
|
||||||
|
data_bits: 8
|
||||||
stop_bits: 1
|
stop_bits: 1
|
||||||
parity: NONE
|
parity: NONE
|
||||||
|
|
||||||
# Modbus-Komponente (der Hub)
|
# --- Base Modbus component for the bus ---
|
||||||
modbus:
|
modbus:
|
||||||
- id: modbus1
|
- id: modbus_hub
|
||||||
uart_id: uart_bus
|
uart_id: uart_bus
|
||||||
|
|
||||||
|
# --- Modbus Controller for the specific valve device ---
|
||||||
modbus_controller:
|
modbus_controller:
|
||||||
- id: valve_device
|
- id: valve_controller
|
||||||
address: 0x01
|
modbus_id: modbus_hub
|
||||||
modbus_id: modbus1
|
address: 0 # The Modbus address of your valve. Change if not 0.
|
||||||
|
# update_interval: 1s
|
||||||
number:
|
|
||||||
- platform: modbus_controller
|
|
||||||
modbus_controller_id: valve_device
|
|
||||||
id: valve_controller_command
|
|
||||||
name: "Valve Control"
|
|
||||||
address: 0x01
|
|
||||||
value_type: U_WORD
|
|
||||||
# min_value: 0
|
|
||||||
# max_value: 2
|
|
||||||
# step: 1
|
|
||||||
|
|
||||||
globals:
|
|
||||||
- id: my_valve_is_open
|
|
||||||
type: bool
|
|
||||||
restore_value: false
|
|
||||||
initial_value: 'true'
|
|
||||||
|
|
||||||
valve:
|
|
||||||
- platform: template
|
|
||||||
name: "Modbus Ventil"
|
|
||||||
id: my_modbus_valve
|
|
||||||
|
|
||||||
# Lambda, um den aktuellen Zustand zu bestimmen
|
|
||||||
# Liest den Zustand aus der globalen Variable
|
|
||||||
lambda: |-
|
|
||||||
return id(my_valve_is_open);
|
|
||||||
|
|
||||||
# Aktion beim Drücken auf "Öffnen"
|
|
||||||
open_action:
|
|
||||||
- number.set:
|
|
||||||
id: valve_controller_command
|
|
||||||
value: 1
|
|
||||||
- globals.set:
|
|
||||||
id: my_valve_is_open
|
|
||||||
value: 'true'
|
|
||||||
|
|
||||||
# Aktion beim Drücken auf "Schliessen"
|
|
||||||
close_action:
|
|
||||||
- number.set:
|
|
||||||
id: valve_controller_command
|
|
||||||
value: 2
|
|
||||||
- globals.set:
|
|
||||||
id: my_valve_is_open
|
|
||||||
value: 'false'
|
|
||||||
|
|
||||||
# (Optional) Aktion beim Drücken auf "Stopp"
|
|
||||||
stop_action:
|
|
||||||
- number.set:
|
|
||||||
id: valve_controller_command
|
|
||||||
value: 0
|
|
||||||
|
|
||||||
|
# ===================================================================
|
||||||
|
# SENSORS - COMPLETE
|
||||||
|
# ===================================================================
|
||||||
sensor:
|
sensor:
|
||||||
- platform: modbus_controller
|
# This sensor reads the raw 16-bit value from the valve's input register.
|
||||||
modbus_controller_id: valve_device
|
- platform: modbus_controller
|
||||||
name: "Supply Voltage"
|
modbus_controller_id: valve_controller
|
||||||
register_type: read
|
name: "Valve Raw Status"
|
||||||
device_class: voltage
|
id: valve_raw_status
|
||||||
entity_category: diagnostic
|
internal: true # Hide from Home Assistant UI
|
||||||
accuracy_decimals: 2
|
register_type: read # 'read' is the valid type for input registers
|
||||||
|
address: 0x0000 # The address of the register to read
|
||||||
|
value_type: U_WORD # Read the full 16-bit unsigned word
|
||||||
|
- platform: modbus_controller
|
||||||
|
modbus_controller_id: valve_controller
|
||||||
|
name: "VDD"
|
||||||
|
id: valve_vdd
|
||||||
|
register_type: read # 'read' is the valid type for input registers
|
||||||
|
address: 0x00FC # The address of the register to read
|
||||||
|
value_type: U_WORD # Read the full 16-bit unsigned word
|
||||||
|
entity_category: diagnostic # Mark as diagnostic
|
||||||
|
unit_of_measurement: "V"
|
||||||
|
accuracy_decimals: 2 # Show two decimal places
|
||||||
|
# Apply filters to convert the raw value to volts and update periodically
|
||||||
filters:
|
filters:
|
||||||
- lambda: |-
|
- lambda: |-
|
||||||
return x / 1000.0;
|
// Convert the raw VDD value to volts
|
||||||
address: 0x00F5
|
return x / 1000.0; // Assuming the value is in millivolts
|
||||||
unit_of_measurement: "V"
|
- heartbeat: 60s # Update every 60 seconds
|
||||||
value_type: U_WORD
|
- delta: 200 # Only update if the value changes by more than 200 mV
|
||||||
|
|
||||||
|
# ===================================================================
|
||||||
|
# TEXT SENSORS FOR HUMAN-READABLE STATUS
|
||||||
|
# ===================================================================
|
||||||
|
text_sensor:
|
||||||
|
# 1. This text sensor extracts the HIGH BYTE for the operation status.
|
||||||
|
- platform: template
|
||||||
|
name: "Valve Operation"
|
||||||
|
id: valve_operation_status
|
||||||
|
icon: "mdi:state-machine"
|
||||||
|
lambda: |-
|
||||||
|
// Extract the high byte from the raw status sensor
|
||||||
|
// using a bitwise right shift.
|
||||||
|
int operation_code = (int)id(valve_raw_status).state >> 8;
|
||||||
|
switch (operation_code) {
|
||||||
|
case 0: return {"Idle"};
|
||||||
|
case 1: return {"Opening"};
|
||||||
|
case 2: return {"Closing"};
|
||||||
|
case 3: return {"Obstacle Detected"};
|
||||||
|
case 4: return {"End Position Not Reached"};
|
||||||
|
default: return {"Unknown Operation"};
|
||||||
|
}
|
||||||
|
|
||||||
|
# 2. This text sensor extracts the LOW BYTE for the current valve state.
|
||||||
|
- platform: template
|
||||||
|
name: "Valve Position"
|
||||||
|
id: valve_position_status
|
||||||
|
icon: "mdi:valve"
|
||||||
|
lambda: |-
|
||||||
|
// Extract the low byte from the raw status sensor
|
||||||
|
// using a bitwise AND mask.
|
||||||
|
int state_code = (int)id(valve_raw_status).state & 0xFF;
|
||||||
|
switch (state_code) {
|
||||||
|
case 0: return {"Closed"};
|
||||||
|
case 1: return {"Open"};
|
||||||
|
default: return {"Unknown"};
|
||||||
|
}
|
||||||
|
|
||||||
|
# ===================================================================
|
||||||
|
# THE MAIN VALVE COMPONENT
|
||||||
|
# ===================================================================
|
||||||
|
valve:
|
||||||
|
- platform: template
|
||||||
|
name: "Modbus Controlled Valve"
|
||||||
|
id: modbus_valve
|
||||||
|
optimistic: false
|
||||||
|
# The lambda determines the current state (open or closed) of the valve.
|
||||||
|
lambda: |-
|
||||||
|
int state_code = (int)id(valve_raw_status).state & 0xFF;
|
||||||
|
if (state_code == 1) {
|
||||||
|
return true; // Open
|
||||||
|
} else if (state_code == 0) {
|
||||||
|
return false; // Closed
|
||||||
|
} else {
|
||||||
|
return {}; // Unknown
|
||||||
|
}
|
||||||
|
# Action to execute when the "OPEN" button is pressed.
|
||||||
|
open_action:
|
||||||
|
- lambda: |-
|
||||||
|
// Use the send() command inherited from ModbusDevice
|
||||||
|
// Function 0x06: Write Single Register
|
||||||
|
// Payload for value 1 is {0x00, 0x01}
|
||||||
|
const uint8_t data[] = {0x00, 0x01};
|
||||||
|
id(valve_controller).send(0x06, 0x0000, 1, 2, data);
|
||||||
|
# Action to execute when the "CLOSE" button is pressed.
|
||||||
|
close_action:
|
||||||
|
- lambda: |-
|
||||||
|
// Payload for value 2 is {0x00, 0x02}
|
||||||
|
const uint8_t data[] = {0x00, 0x02};
|
||||||
|
id(valve_controller).send(0x06, 0x0000, 1, 2, data);
|
||||||
|
# Action to execute when the "STOP" button is pressed.
|
||||||
|
stop_action:
|
||||||
|
- lambda: |-
|
||||||
|
// Payload for value 3 is {0x00, 0x03}
|
||||||
|
const uint8_t data[] = {0x00, 0x03};
|
||||||
|
id(valve_controller).send(0x06, 0x0000, 1, 2, data);
|
||||||
|
|
|
||||||