irrigation_system/software
Eduard Iten 1067796df4 fix(slave_node): Stabilize Modbus RTU communication
The Modbus server was previously unstable, leading to intermittent CRC errors when polled by a master. This was caused by the main thread exiting after initialization, which created timing and race condition issues for the interrupt-driven Modbus stack.

This fix ensures the main thread continues to run in a low-power sleep loop (). This provides a stable context for the Modbus server, resolving the CRC errors and ensuring reliable communication.
2025-07-01 14:30:22 +02:00
..
.vscode canbus, modbus working, valve has to be implemented in real 2025-06-19 16:56:21 +02:00
apps fix(slave_node): Stabilize Modbus RTU communication 2025-07-01 14:30:22 +02:00
boards/iten/bluepill_f103rb feat: Establish functional multi-app structure 2025-07-01 11:05:12 +02:00
lib feat(project): Restructure software for multi-app setup 2025-07-01 08:20:25 +02:00