- Updated Doxygen comments in header files (valve.h, fwu.h, modbus_server.h) to be consistent and in English.
- Translated German register names in docs/modbus-registers.de.md to English.
- Updated docs/concept.de.md to reflect new details on current measurement and sensors.
- Updated docs/planning.de.md to reflect completed tasks in Phase 1.
Added Doxygen-style comments to all C source and header files in the
and directories. This improves
code documentation and enables VSCode tooltip help.
Additionally, short inline comments were added to all global variables
for better clarity.
Adds a new `adc_sensor` library to abstract reading analog values from ADC channels. The output of this library is currently simulated.
This library is now used by the `modbus_server` to read the motor current and the main supply voltage, replacing the previous implementation. This change improves modularity by centralizing ADC-related code into a dedicated module.
The build system has been updated to include the new library.
This commit introduces application versioning, exposing version information through the Modbus server and logging it at startup.
- Add to provide version information
- Update to log the application version at startup
- Update to expose firmware version via Modbus
- Add file association for in
This commit enhances the Modbus server's configuration handling by:
- Loading saved baudrate and unit ID settings during initialization, ensuring persistence across reboots.
- Providing improved feedback during `modbus_reconfigure`, including logging for successful changes and informing the user when a device restart is required for changes to take effect.
- Saving new configuration settings even if immediate reinitialization fails, allowing them to be applied on the next boot.
This commit introduces a new Modbus input register for the system's supply voltage.
- The `modbus-registers.de.md` documentation is updated to include the `SUPPLY_VOLTAGE_MV` register at address `0x00F5` within the system block.
- The `modbus_server.h` header defines the new register.
- The `modbus_server.c` implementation provides a fixed value (12300 mV) for this register.
- The `modbus_tool.py` script is updated to read and display this new supply voltage value in the UI.
This lays the groundwork for integrating actual voltage measurements in the future.
This commit introduces a major refactoring of the project structure to align
with Zephyr's recommended multi-application and library organization.
Key changes include:
- Relocation of custom modules from 'software/modules/' to 'software/lib/'.
- Introduction of a central 'software/CMakeLists.txt' to manage application
and library subdirectories.
- Creation of new Kconfig files for 'software/' and 'software/apps/slave_node/'
to define project-wide and application-specific configurations.
- Removal of the 'gateway' and 'stm32g431_tests' applications.
- Removal of 'shell_modbus.c' and 'shell_system.c' from 'slave_node' application's
direct source files, indicating a shift towards library-based shell commands.
- Updates to 'software/apps/slave_node/CMakeLists.txt', 'prj.conf', and
'boards/bluepill_f103rb.conf' to reflect the new structure and dependencies.